Storage & power conversion

Battery storage that keeps working after sunset

Lithium storage from a single 5 kWh wall unit to industrial cabinet blocks, and the hybrid inverters and charge controllers that tie generation, storage, grid and load together.

Battery range

Choose a storage system

Current range, availability and configuration pricing

Loading battery products…

ENA Powerwall

Stackable from 5 kWh to 25 kWh

LiFePO4 modules that stack as the load grows, so a household can start at one module and add capacity without replacing the inverter or re-commissioning the system. The same architecture scales into commercial and industrial cabinets for sites measuring storage in hundreds of kilowatt-hours.

Usable energy5 kWh – 25 kWh, stackable
ChemistryLiFePO4
SegmentsResidential, commercial & industrial
ExpansionAdd modules without re-commissioning
MonitoringState of charge, cell temperature and cycles in ENA Control
The front face of an ENA LIT LI wall-mounted battery, with its colour touchscreen showing system state above the ENA logo
The rear of an ENA LIT LI battery showing the wall mounting plate, ethernet-style communication ports, positive and negative DC terminals and the earth stud

ENA LIT LI · wall-mounted

Everything a fitter needs on one face

The LIT LI hangs on its own plate, reads out on the front and lands every connection on the underside: parallel links for stacking, CAN and RS485 to the inverter, DC busbars under covers, and an earth stud. It is sealed, fanless and silent enough to live in a hallway or a plant room.

FormatWall-mounted, integrated mounting plate
ChemistryLiFePO4
InterfaceFront colour touchscreen
CommunicationsCAN and RS485 to the inverter
TerminalsCovered DC busbars, parallel links, earth stud
See every face →

Hybrid inverters & MPPT

1 kVA to 50 kVA and above

Hybrid inverters accept PV, battery, grid and generator inputs and select the right source. The range runs from single-room backup to industrial three-phase duty, with MPPT charge controllers matched to each array instead of added as an afterthought.

Hybrid inverters1 kVA – 50 kVA+, single and three phase
InputsPV, battery, grid, generator
MPPT controllersMatched to the specified array
SwitchingAutomatic transfer switches, distribution boards
MonitoringReports into ENA Control

ENA Hybrid BESS

Where lithium alone will not carry the site

Captive and prime-power installations that have to run through the night and through a bad week pair lithium storage with gas generation, so the battery handles the peaks and the cycling while the gas set carries sustained base load. One controller arbitrates between them.

Peak shaving

The battery takes the spikes, so the generation plant is sized for the average rather than the worst minute of the month.

Prime power

Sites with no usable grid connection run continuously on the hybrid plant, not on a diesel set and a fuel contract.

Second life

Packs that fall below their stationary threshold are triaged and re-graded rather than scrapped at the first derate.

Industrial or campus load?

Storage sizing depends on the measured curve, not the nameplate. The mini-grids page has the estimator and the request form.

Size a project